Jenn-Air, Maytag and Magic Chef Fault Codes
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas supply to oven before
servicing, unless testing requires power and/or gas.
8
16023509 ©2004 Maytag Services
PRODUCT(S): FREESTANDING RANGES, GEMINI AND DOUBLE OVEN
MODELS: MGR6772BD*, MER6549BA*, MER6550AA*, MER6550AC*, MER6550BA*,
MER6550BC*, MER6555AA*, MGR6775AD*, MGR6875AD*, MER6555AA*,
MER6555AC*, MER6751AA*, MER6755AA*, MER6755AC*, MER6775AA*,
MER6775AC*, MER6875AA*, MER6875AC*
Fault
Code
Problem Component(s) to Check
F0-0 No Fault...................................................................... None.
F1-1 Runaway Cook ...........................................................
(Upper Oven)
Check door lock, oven sensor, and harness.
If ok, replace control.
F1-2 Runaway Cook ...........................................................
(Lower Oven)
Check door lock, oven sensor, and harness.
If ok, replace control.
F1-3 Oven temperature above 650˚ F when bake/broiling.
(Upper Oven)
Check door lock, oven sensor, and harness.
If ok, replace control.
F1-4 Oven temperature above 650˚ F when bake/broiling.
(Lower Oven)
Check door lock, oven sensor, and harness.
If ok, replace control.
F1-5 Cancel Key .................................................................
(Upper Oven)
Check that ribbon is making good connection and
inspect ribbon. If ok, replace control.
F1-6 Cancel Key .................................................................
(Lower Oven)
Check that ribbon is making good connection and
inspect ribbon. If ok, replace control.
F1-7 Membrane disconnected............................................ Check that ribbon is making good connection and
inspect ribbon. If ok, replace control.
F1-8 Shorted key in membrane switch ............................... Check that ribbon is making good connection and
inspect ribbon. If ok, replace control.
F1-9 Internal communication error within control ............... Reset power. If error repeats, replace control.
F1-A Control does not see state of lock/unlock switch .......
(Upper Oven)
Check connections on door lock assembly & lock
switch, check wiring from assembly to control.
F1-B Control does not see state of lock/unlock switch .......
(Lower Oven)
Check connections on door lock assembly & lock
switch, check wiring from assembly to control.
F1-C Door switch is not recognized as opened or closed...
(Upper Oven)
Check connections at door switch, check lock
mechanism, check wiring from switch to control.
F1-D Door switch is not recognized as opened or closed...
(Lower Oven)
Check connections at door switch, check lock
mechanism, check wiring from switch to control.
F1-E Control not calibrated ................................................. Replace control.
F1-F Jumper not removed from PCB.................................. Replace control.
F1-H EEPROM read error ................................................... Replace control.
F1-L Sensor Wire................................................................ Ohm wire end to end to ensure a closed path.
F3-1 Sensor open circuit.....................................................
(Upper Oven)
Ohm sensor and harness.
DO NOT REPLACE CONTROL.
F3-2 Sensor circuit open.....................................................
(Lower Oven)
Ohm sensor and harness.
DO NOT REPLACE CONTROL.
F9-1 Latch switch (Upper Oven)......................................... If wire connections ok, replace motorized door lock.
F9-2 Unlock switch (Upper Oven) ...................................... If wire connections ok, replace motorized door lock.
F9-3 Lock and unlock switch (Upper Oven) ....................... If wire connections ok, replace motorized door lock.
F9-4 Lock switch (Lower Oven).......................................... If wire connections ok, replace motorized door lock.
F9-5 Unlock switch (Lower Oven) ...................................... If wire connections ok, replace motorized door lock.
F9-6 Lock and unlock switch (Lower Oven) ....................... If wire connections ok, replace motorized door lock.
Vista de página 7