MODELS: MER6750AA*, MER6750AC*
Fault
Code
Problem Component(s) to Check
F0-0 No Fault........................................................................ None.
F1-1 Oven temperature above 650˚ F when bake/broiling... Check door lock, oven sensor, and harness.
If ok, replace control.
F1-3 Oven temperature above 905˚ F during clean cycle.... Check door lock, oven sensor, and harness.
If ok, replace control.
F1-5 Cancel key not responding .......................................... Ensure ribbon is making good connection and
inspect ribbon. If ok, replace control.
F1-7 Membrane disconnected.............................................. Ensure ribbon is making good connection and
inspect ribbon. If ok, replace control.
F1-8 Shorted key in membrane switch................................. Ensure ribbon is making good connection and
inspect ribbon. If ok, replace control.
F1-9 Slave microprocessor not functioning .......................... Replace control.
F1-A Control does not see state of lock or unlock switches . Check connections on the door lock assembly,
check lock switch with meter, check wiring from
assembly to control.
F1-C Door switch is not recognized as opened or closed .... Check connections at door switch, check lock
mechanism, check wiring from switch to control.
F1-E Control not calibrated ................................................... Replace control.
F1-F Jumper not removed from PCB ................................... Replace control.
F1-H EEPROM error ............................................................. Replace control.
F1-N Microprocessor voltage error ....................................... Replace control.
F3-1 Sensor is shorted or open ............................................ Ohm sensor and harness.
DO NOT REPLACE CONTROL.
F9-1 Door lock will not lock................................................... Check wire connections.
If ok, replace motorized door lock.
F9-2 Door lock will not unlock............................................... Check wire connections.
If ok, replace motorized door lock.
F9-3 Door lock is locked and unlocked at the same time..... Check wire connections.
If ok, replace motorized door lock.