IMPORTANT - PLEASE KEEP FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR
INSTALLATION INSTRUCTIONS
Electric Counter Mounted Surface Units
READ “SAFETY INSTRUCTIONS” IN USE & CARE BOOK BEFORE USING UNIT
In order to assure the best results in service, proper operation and maximum efficiency, the original installation and adjustment
should be madeby your dealer, his authorized agent, or by your local utility company before you attempt to operate the surface
unit.
LOCATION
Place unit where it will be well lighted. For proper cooking results, it must be level. THESE ELECTRIC COUNTER MOUNTED
SURFACE UNITS ARE APPROVED FOR I NSTALLATION IN COMBUSTIBLE CABINETRY. SEE INSTALLATION
DIAGRAM FOR THE APPROPRIATE UNIT ON THE FOLLOWING PAGES OF THIS INSTRUCTION SHEET.
OUTSIDE WIRING
Your local utility company will tell you whether the present
electric service to your home is adequate. It may be
necessary to increase the size of the wiring to the house and
service switch to take care of the electrical load demanded
by the surface unit and/or oven. The wattage (K.W. rating)
load for the range is specified on the name plate on the unit.
HOUSE WIRING
Most local building regulations and codes require that all
electrical wiring be done by licensed electricians. All wiring
should conform to Local and National Electrical Codes. This
unit requires a single phase three wire 120/240 or a 120/208
volt, 60 Hz, AC circuit. Wiring codes require that a separate
circuit be run from the main entrance panel to the unit and
that it be equipped with separate disconnect switch and
fuses, either in the main entrance panel or in a separate
switch and fuse box.
UNIT CONNECTIONS
This unit is supplied with a 240/208 volt wiring system
consisting of 2 insulated conductors and 1 bare grounding
wire for use on a 3 wire 120/240 or a 120/208 volts, 60 Hz,
AC branch circuit. The flexible armored conduit supplied
with the unit must be connected to an approved electrical
junction box by means of an approved conduit to box
connector.
THE BAREWIRE IN THEUNIT CONDUIT ISCONNECTED
TOTHEFRAMEOFTHEUNIT.THEFRAMEOF THEUNIT
IS GROUNDED TO NEUTRAL OF THE BRANCH CIRCUIT
ONLY WHEN THI S BARE WIRE IS CONNECTED TO THE
NEUTRAL (WHITE) WIRE OF THE BRANCH CIRCUIT. If
used on new branch-circuit installations (1996 NEC), mobile
homes, recreational vehicles, or in an area where local
codes prohibit grounding through the neutral conductor, the
bare wire at the end of the unit conduit must be used to
ground the unit in accordance with local code. The red and
black wires must be connected to two conductors (red and
black) of the branch circuit. The neutral (white) wire of the
branch circuit must be properly insulated. Connect all wires
to the branch circuit with approved connectors. Use copper
or aluminum wire. If aluminum wire is used, use connectors
recognized for joining aluminum to copper.
RANGE GROUNDED THROUGH NEUTRAL CONDUCTOR
WIRING METHOD IF CODE DOES NOT PERMIT G ROUNDING
THROUGH NEUTRAL CONDUCTOR & ALSO REQUIRED IN MOBILE
HOMES.
WARNING: Be sure UNIT is DISCONNECTED from
POWER SUPPLY before examining any of the electrical
equipment.
8101P408-60
(05-02-01)
REDBLACK
RANGE CONDUIT
BARE
APPROVED
CONNECTOR
APPROVED
BOX
L1
L2NEUTRAL
APPROVED INSULATED
CONNECTIONS
BRANCH CIRCUIT
(POWER SUPPLY)
APPROVED
CONNECTOR
BLACK
INSULATED
L1
NEUTRAL
RANGE CONDUIT
RED
BARE
APPROVED BOX
APPROVED INSULATED
CONNECTIONS
L2
SEPARATE GROUND
BRANCH CIRCUIT
(POWER SUPPLY)
Vista de página 0
1 2 3 4 5 6 7 8 9

Resumo do Conteúdo

Página 1 - INSTALLATION INSTRUCTIONS

IMPORTANT - PLEASE KEEP FOR THE USE OF THE LOCAL ELECTRICAL INSPECTORINSTALLATION INSTRUCTIONSElectric Counter Mounted Surface UnitsREAD “SAFETY INSTR

Página 2 - 3/8² FLEXIBLE CABLE 3′ MIN

2Units shown in figures 1 and 2 may be installed incombustible countertop and must be spaced at least (1²from) combustible sides and rear wall above c

Página 3 - 30² Smoothtop Ceramic Cooktop

336² Cooktop with Coil ElementsFIGURE 230² Smoothtop Ceramic CooktopFIGURE 33/8² FLEXIBLE CABLE 48² LONGFURNISHED AND INSTALLED BYMANUFACTURER (CONNEC

Página 4 - INSTRUCCIONES DE INSTALACIÓN

IMPORTANTE — CONSERVE ESTOS MATERIALES PARA USO DEL INSPECTOR ELÉCTRICO LOCALINSTRUCCIONES DE INSTALACIÓNUnidades eléctricas de superficie montadas en

Página 5 - FIGURA 1

2Si la superficie se va a asegurar al mostrador, quite la parte superior principal y sujete la caja del quemador al mostrador en lascuatro (4) esquina

Página 6

3Superficie para cocinar con elementos de espiral de 36²²²²FIGURA 2Superficie para cocinar lisa de cerámica de 30²²²²FIGURA 3CABLE FLEXIBLE DE 3/8² DE

Página 7 - MISE EN SERVICE

IMPORTANT - CONSERVER À L’USAGE DE L’INSPECTEUR EN ÉLECTRICITÉ LOCALMISE EN SERVICEPlaques de cuisson électriques montés sur un comptoirLIRE LES “MESU

Página 8 - INFÉRIEURE

2Si la plaque de cuisson doit être fixée au comptoir, retirer le dessus et fixer la boîte des brûleurs aux comptoir aux 4 coins.Pour retirer le dessus

Página 9

3Plaque de cuisson de 91,4 cm avec éléments tubulairesFIGURE 2Plaque de cuisson en vitrocéramique de 76,2 c mFIGURE 3CÂBLE FLEXIBLE DE 9,5 MM DEDIAMÈT

Comentários a estes Manuais

Sem comentários